DESCRIZIONE
G1126P-24-410W IP-COM
24GE+2SFP Ethernet Unmanaged Switch With24-Port PoE
- Compliant with IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3z, IEEE802.3x and IEEE802.3af/at standards.
- 24 * 100/1000 Mbps Base-T RJ45 ports for data transmission and power supply.
- 2 * 1000 Mbps Base-X SFP slots.
- 8K MAC address table and MAC address auto-learning.
- IEEE 802.3x-compliant full-duplex flow control and half-duplex backpressure flow control.
- 48Gbps backplane bandwidth.
- Maximum power consumption of a single port: 30W.
- Maximum power consumption of the switch: 410W.
- 4 modes: standard, priority, extend and VLAN.
- Rack mounting.
Caratteristiche tecniche
| Model | G1126P-24-410W |
| Interfaces | 24 * 100/1000 Mbps Base-T RJ45 ports (Data/Power) 2* 1000 Mbps Base-X SFP port |
| Lightning protection | ≥6KV |
| Forwarding mode | Store-and-forward |
| Switching capability | 48 Gbps |
| Packet forwarding rate | 35.7 Mpps |
| Buffer | 2M |
| MAC address table | 8K |
| PoE supply | Ports 1-24 support standard IEEE802.3af/at 30W output per PoE port 370W output of the total PoE Power |
| Power consumption | 410W output the whole device |
| Input voltage | AC: 100-240V~50/60Hz |
| Dimensions | 440*284*44mm |
| Four Modes | Standard: Default mode of the switch. In this mode, it works as an unmanaged switch;all ports can communicate with each other separately. Priority: In this mode, port 23,24,SFP1 and SFP2 serve as uplink ports, ports 1 ‒ 8 serve as high priority port. All ports can communicate with each other separately. Extend: In this mode, data rate of ports 17 - 22 reduces to 10 Mbps, the maximum transmission distance can be 250 meters, and all ports can communicate with each other. VLAN: In this mode, ports 1 - 22 of the switch can communicate with port 23,24, SFP1, SFP2 separately, but cannot communicate with each other. You can enable this mode to reduce broadcast storm and isolate DHCP broadcast. |
| Operating environment | Operating Temperature: 0℃~45℃ (32℉~113℉) Storage Temperature: -40℃~70℃ (-40℉~158℉) Operating Humidity: 10%~90% non-condensing Storage Humidity: 5%~90% non-condensing |
| Certificates | FCCã€CEã€RoHS |
NT-TEG1128P-250
OMA-SG2210P
NT-TEG1120P-150
IC-G1110P-150
IC-G5310P-150
TL-SG1005P-PD
IC-G3310P-150
NT-TEF1110P-63
NT-TEG1105P-63
NT-TEF1118P-150
NT-TEF1105P-38
OMA-SG2008P
NT-TEF1109P-63
IC-G1116P-150
TL-SF1009P
TL-SG1005P
NT-TEF1109P-102
IC-G3326P-410
NT-TEF1226P-410
IC-G1120P-250
NT-TEF1210P-150
OMA-SG3210XHPM2
OMA-ES205GP
OMA-ES210GMP
IC-G3318P-250
NT-TEF1110P-102
IC-G1105P-63
OMA-SG2428LP
OMA-SG6654XHP
IC-G5328XP-410
NT-TEF1106P-63
NT-TEF1126P-250
NT-TEF1218P-250
TL-SF1005LP